Edge Collective

14

Edge Collective's pedagogical efforts. Misc. Project notes.

Edge Field School

some ideas

initial mix

certifications / education to seek and teach

inserting date using vi

Mon Jun 26 02:39:29 PM EDT 2023

Smithereen

Greenhouse sensors

How long a cable can we use on the ds18b20?

nice discussion here

https://www.analog.com/en/technical-articles/guidelines-for-reliable-long-line-1wire-networks.html

Suggestion:

Use CAT-5 cable twisted pair. Ground any unused wires. Should be able to get approx 100' distance without trouble.

Sensor drying technniques

Testing a 'soil moisture' probe technique for the tomato plant, too?

Purchase an Acclima sensor for soil moisture?

https://www.researchgate.net/publication/353983263_Review_of_research_progress_on_soil_moisture_sensor_technology

Hardie, "Review of Novel and Emerging Proximal Soil Moisture Sensors for Use in Agriculture" https://www.mdpi.com/1424-8220/20/23/6934

https://hcs.osu.edu/sites/hcs/files/imce/files/soil-moisture-sensors.pdf

https://extension.umn.edu/irrigation/soil-moisture-sensors-irrigation-scheduling#time-domain-reflectometry-%28tdr%29-sensors-1869261

Good review of soil moisture techniques, including Acclima, here: https://agupubs.onlinelibrary.wiley.com/doi/full/10.1029/2018RG000618

Comparing Acclima and other soil moisture sensors: https://www.mdpi.com/1424-8220/18/11/3786

The performance of five types of commercially available soil moisture sensors was evaluated at two fields with significantly different salinity levels and clay contents. The sensors included TDR315, CS655, GS1, SM100, and CropX. The accuracy of each sensor was determined by comparing its readings with gravimetric measurements of soil water content obtained at several times during the study period. In general, all sensors responded to wetting and drying events. The TDR315, CS655, and GS1 sensors had acceptable accuracies for managing irrigations at the site with low salinity and low clay content (LSLC) based on root mean square error (RMSE). However, none of the sensors performed satisfactorily at the site with high salinity and high clay content (HSHC), with RMSE estimates that were up to eight times larger compared to the values at LSLC. In addition, high levels of noise were observed in TDR315 due to high salinity and out-of-range responses and consequently missing readings in case of CS655 sensor. A potential solution for using soil moisture sensors in irrigation scheduling under such conditions is the use of site-specific calibrations.

Tue Jul 4 11:26:57 PM EDT 2023

Pumped hydro:

https://re100.anu.edu.au/#share=g-d39a5688446926d55bf059716f828959